3U vs 4U serverové stojanové baterie: Průvodce výběrem datového centra

Obsah

The uninterrupted operation of server infrastructure and crucial IT assets stands as a top priority, particularly in the face of main power failure. For equipment housed in racks—those tall cabinets holding your IT gear—reliable backup batteries are essential and reside directly within the rack.

Server Rack batteries, however, come in different physical sizes. You’ll typically encounter two common heights: 3U and 4U. Choosing between them significantly impacts backup power capacity and rack space utilization.

Kamada Power As a baterie do serverového stojanu expert, this guide breaks down the key differences to help you determine the best fit for your setup.

Kamada power server rack battery

Understanding Rack Units (U)

The standardized height for equipment in a server rack is defined by the Rack Unit (U). A server rack is a cabinet with standardized slots.

Definition: One U equals 1.75 inches (44.45 mm).

  • A 3U battery needs three vertical rack units, about 5.25 inches high.
  • A 4U battery requires four units, around 7 inches high.

Understanding U size is crucial because usable rack space is always a premium. The battery unit’s size directly impacts available vertical space. It also influences internal battery unit design, impacting potential cell capacity and thermal management.

3U vs 4U: Core Technical Differences

Size and Rack Space

The most obvious difference is height: 4U is taller than 3U, allowing fewer 4U units vertically in a rack. The larger 4U box offers more internal volume, beneficial for design flexibility.

Capacity & Power Density

  • Kapacita: Total energy stored (Ah/kWh). A larger 4U unit typically holds more cells, offering higher total capacity for longer runtimes.
  • Power Density: Measures power per rack unit. While 4U has higher total capacity, well-designed 3U units can be surprisingly potent for their size (high power density per U).

Cooling and Thermal Management

Battery health and performance are highly sensitive to temperature. More internal space in a 4U unit typically facilitates better airflow and allows for more robust cooling component integration, helping manage heat effectively. Effective cooling is required for both, but optimal design can be easier with the larger internal volume of a 4U, especially under heavy load.

Weight & Installation

Higher capacity usually means more weight; 4U batteries are generally heavier than 3U units. Installing heavier 4U units is more challenging, often requiring more people or specialized lifting equipment for safety.

Connectivity & Monitoring

Battery units connect to the UPS and system monitoring. Both sizes offer connection points. Integrated systems monitor battery status and health (e.g., BMS). Extra space in 4U může allow for more accessible ports or sophisticated internal monitoring.

Choosing the Right Size: 3U or 4U?

Your decision hinges on aligning battery capabilities with operational needs and environment realities. Consider these factors:

Why Choose 3U?

  • Rack space is severely limited.
  • Only short duration backup is needed.
  • Deploying in multiple smaller locations.
  • Consistency with other 3U rack equipment.

Why Choose 4U?

  • Extended backup runtime is required.
  • Consolidating capacity into fewer units.
  • The operating environment demands better thermal management.
  • Planning for future expansion.

Battery Chemistry: Li-ion vs. VRLA

Beyond size, the battery chemistry inside significantly impacts performance, lifespan, weight, and cost.

Lithium-ion (Li-ion)

Li-ion batteries (like LFP) are lighter and more energy-dense than traditional Lead-Acid. Higher energy density allows more capacity in compact sizes (like 3U). They offer significantly longer lifespan, require less routine maintenance, and feature an integrated BMS for monitoring.

VRLA Lead-Acid

VRLA (Valve Regulated Lead-Acid), including AGM/Gel, is the standard traditional rack technology. Compared to Li-ion, VRLA is heavier, less energy-dense, and takes more space/weight for same capacity. Main advantage: Lower upfront cost. However, VRLA generally has a shorter lifespan (particularly affected by heat and deep discharge) and requires more hands-on maintenance compared to Li-ion with advanced BMS. Lower density/weight capacity means high capacity VRLA often needs larger footprints (4U+) than Li-ion.

Installation, Maintenance, and TCO

Instalace

Weight is key for installation. Heavier 4U units may require more help or lifting equipment than 3U units.

Údržba

VRLA requires more routine, hands-on maintenance. Li-ion with BMS offers more automated monitoring and less manual intervention.

Total Cost of Ownership (TCO)

Analyze Total Cost of Ownership (TCO), not just upfront price. Includes:

  • Initial purchase price.
  • Installation expense.
  • Maintenance labor/costs.
  • Cost/frequency of replacement.

VRLA: lower initial cost, potentially higher TCO (shorter life, more maintenance). Li-ion: higher initial cost, potentially lower TCO (longer life, less maintenance).

Závěr

3U vs 4U baterie do serverového stojanu choice is critical. Size impacts rack space and max unit capacity. Also evaluate chemistry: Li-ion (energy-dense) vs. VRLA (traditional, lower initial cost).

Your final decision aligns with operational needs:

  • Available rack space
  • Required backup runtime/capacity
  • Environmental conditions (especially temp)
  • Budget (TCO) vs. long-term cost
  • Future expansion plans

Review technical specs thoroughly. Consult experts if unsure to ensure the best fit. Choosing the right size and chemistry is a strategic decision for optimizing performance and ensuring business continuity.

Kamada Power Server Rack Battery manufacturers in China, specializing in custom server rack batteries. Kontakt kamada napájení. Get Quotation.

ČASTO KLADENÉ DOTAZY

Q: Can 3U and 4U batteries be mixed within the same backup power system?

A: Generally, no. Mixing batteries of different sizes, capacities, models, ages, or chemistries within the same backup string is typically not recommended due to performance and safety risks. Best practice dictates using identical batteries throughout a single backup string for optimal performance and reliability.

Q: Does a 4U battery vždy offer longer runtime than a 3U?

A: Not necessarily. While 4U units generally accommodate more total capacity, a high-capacity 3U Li-ion battery might offer similar or longer runtime than some 4U VRLA models. Compare specific Ah/kWh ratings and published runtime charts for your load.

Q: How does heat affect 3U vs 4U batteries differently based on their size?

A: High temperatures harm all batteries, speeding aging. While size itself doesn’t change chemistry sensitivity, a larger 4U může offer more internal space for better cooling than a dense 3U. Effectiveness varies by model’s thermal design.

Q: Is installing a 4U battery significantly harder than a 3U?

A: Yes, primarily due to weight. Heavier 4U units are more challenging to lift/position safely and often require more help or specialized equipment than 3U units.

Q: What’s the main advantage of choosing a Lithium-ion battery in a 3U size?

A: Maximizing capacity in limited rack footprint. Li-ion’s superior energy density allows significantly more Ah/kWh capacity in a 3U unit than a VRLA of the same size, ideal when rack space is limited but substantial runtime is needed.

Komentáře

Další blogy

Další poznatky a trendy v oblasti lithiových baterií získáte z našeho blogu.

3U vs 4U serverové stojanové baterie: Průvodce výběrem datového centra

Nepřetržitý provoz serverové infrastruktury a klíčových prostředků IT je nejvyšší prioritou, zejména v případě výpadku hlavního napájení. Pro zařízení umístěná ve stojanech - těchto vysokých skříních, v nichž je uloženo IT vybavení - jsou nezbytné spolehlivé záložní baterie, které jsou umístěny přímo ve stojanu. Baterie pro serverové stojany se však dodávají v různých fyzických velikostech. Obvykle se jedná o

Přečtěte si více "

Co znamená jednotka U v serverových skříních

Vstup do serverovny nebo dokonce jen pohled na rack může zpočátku působit zmateně. Jak se tam všechno to vybavení vejde? V tom případě přichází na řadu jednotka U (Rack Unit). Jedná se o standardní měřítko vertikálního prostoru v serverových skříních. Porozumění písmenu "U" je klíčové pro každého, kdo pracuje se serverovým hardwarem - přesně vám řekne, že

Přečtěte si více "

Baterie pro montáž na stěnu vs. baterie do serverového stojanu, která je pro vás nejlepší?

Výběr správného úložiště energie je zásadní, ať už bojujete s výpadky proudu, vysokými náklady na elektřinu, nebo se snažíte o energetickou nezávislost. Jakmile se rozhodnete pro baterii, objeví se klíčové rozcestí: elegantní baterie pro montáž na stěnu nebo funkční baterie pro montáž do serverového stojanu. Která cesta je pro vás ta pravá? Jako odborník na baterie kamada Power v Číně

Přečtěte si více "
logo kamada power

Shrňte své podnikání tak, aby se návštěvník mohl seznámit s vaší nabídkou na kterékoli stránce vašeho webu.

Spojte se s námi

123 Main Street
New York, NY 10001

© 2025 Všechna práva vyhrazena.

Dotaz

Náš tým vám zašle nejlepší nabídku do 20 minut.