서버 랙에서 랙 유닛 U는 무엇을 의미합니까?

목차

Stepping into a server room or even just looking at a rack can initially seem confusing. How does all that gear fit? That’s where the Rack Unit, or “U,” comes in. It’s the standard measure for vertical space in server racks. Understanding ‘U’ is key for anyone handling server hardware – it tells you exactly how much vertical room equipment is needed. It simplifies fitting everything. Stick with me, and we’ll nail down what a rack unit is, how you can figure out your own gear’s size, run through the useful conversions, and look at how those rack holes work.

Kamada Power 1U 2U 3U 4U 5U Server Rack Battery

What Does the Rack Unit U Mean?

A Rack Unit (U or RU) is basically how we measure how tall equipment is when it’s built to go into a server rack.

  • It’s a Set Height: Listen, one Rack Unit (1U) is always 1.75 inches tall. That’s the absolute core measurement everything else in the rack world is based on. (Yep, that also comes out to 44.45 mm in metric).
  • It’s Official: This isn’t just some size someone decided on randomly. This standard measurement comes from the Electronic Industries Alliance (EIA-310 standard). That’s key because it’s what guarantees gear made by different companies will physically fit into those standard racks built to the same spec.
  • It Sizes Gear: Your equipment – things like servers, network switches, batteries, you name it – all come in heights that are exact multiples of this U size (so you get 1U, 2U, 4U, and so on). They’re designed to stack up perfectly.
  • It Sizes Racks: And the racks themselves? They’re sized too, based on the total U count they can hold vertically (like those big 42U racks you see everywhere).

How to Calculate Rack Units

Do you have a device and need its U size? Use this quick method. It helps plan rack space without guessing.

단계What to Do
1Measure Height: Find the device’s total vertical height. Don’t include extra bumps or handles.
2Use Inches: Convert that height to inches if needed (1 inch = 25.4 mm).
3Divide: Divide the height in inches by 1.75 (inches per U).

Formula:

U = Device Height (in inches) ÷ 1.75

예시:

  • A server measures 5.25 inches tall.
  • Calculation: 5.25 ÷ 1.75 = 3U.
  • It’s a 3U server.

This simple math helps confirm the device size for correct placement in your rack.

Server Rack Unit Conversion

Need to switch between U, inches, millimeters, or centimeters? These conversions are helpful.

The core factors are: 1U = 1.75 inches = 44.45 mm = 4.445 cm.

These simple conversions save time when checking specs or dimensions.

Rack U to Inches

One rack unit is always 1.75 inches.

Formula:

1U = 1.75 inches

예시:

  • A 3U device = 3 × 1.75 = 5.25 inches tall.

1U to Inches

Exactly 1U height is 1.75 inches.

Formula:

1U = 1.75 inches

This is the fundamental conversion you need to know.

Rack Unit to Millimeters

To convert U to millimeters, multiply the number of U’s by 44.45 mm.

Formula:

Height (mm) = U × 44.45

예시:

  • A 4U device = 4 × 44.45 = 177.8 mm tall.

Rack Unit to Centimeters

To convert U to centimeters, multiply the number of U’s by 4.445 cm.

Formula:

Height (cm) = U × 4.445

예시:

  • A 5U device = 5 × 4.445 = 22.225 cm tall.

Rack Unit Conversion Formula

Here are the core conversions:

1U = 1.75 inches = 44.45 millimeters = 4.445 centimeters

Rack U Size Chart

Rack Unit(u)RU Height(mm)RU Height(inch)RU Height(cm)
1U44.45mm1.75″4.445cm
2U88.90mm3.50″8.890cm
3U133.35mm5.25″13.335cm
4U177.80mm7.00″17.780cm
5U222.25mm8.75″22.225cm
6U266.70mm10.50″26.670cm
7U311.15mm12.25″31.115cm
8U355.60mm14.00″35.560cm
9U400.05mm15.75″40.005cm
10U444.50mm17.50″44.450cm
11U488.95mm19.25″48.895cm
12U533.40mm21.00″53.340cm
13U577.85mm22.75″57.785cm
14U622.30mm24.50″62.230cm
15U666.75mm26.25″66.675cm
16U711.20mm28.00″71.120cm
17U755.65mm29.75″75.565cm
18U800.10mm31.50″80.010cm
19U844.55mm33.25″84.455cm
20U889.00mm35.00″88.900cm
21U933.45mm36.75″93.345cm
22U977.90mm38.50″97.790cm
23U1022.35mm40.25″102.235cm
24U1066.80mm42.00″106.680cm
25U1111.25mm43.75″111.125cm
26U1155.70mm45.50″115.570cm
27U1200.15mm47.25″120.015cm
28U1244.60mm49.00″124.460cm
29U1289.05mm50.75″128.905cm
30U1333.50mm52.50″133.350cm
31U1377.95mm54.25″137.795cm
32U1422.40mm56.00″142.240cm
33U1466.85mm57.75″146.685cm
34U1511.30mm59.50″151.130cm
35U1555.75mm61.25″155.575cm
36U1600.20mm63.00″160.020cm
37U1644.65mm64.75″164.465cm
38U1689.10mm66.50″168.910cm
39U1733.55mm68.25″173.355cm
40U1778.00mm70.00″177.800cm
41U1822.45mm71.75″182.245cm
42U1866.90mm73.50″186.690cm
43U1911.35mm75.25″191.135cm
44U1955.80mm77.00″195.580cm
45U2000.25mm78.75″200.025cm
46U2044.70mm80.50″204.470cm
47U2089.15mm82.25″208.915cm
48U2133.60mm84.00″213.360cm

Rack Hole and Rack Unit Relationship

Take a real close look at the vertical rails inside any standard server rack, and you’re gonna see a bunch of holes running up and down. These aren’t random! These rack holes are exactly where you bolt your gear in, whether you’re using screws or cage nuts. And here’s the neat part: they line up perfectly with the Rack Unit system we’ve been talking about. Understanding their pattern makes working with racks much clearer.

What is a Rack Unit (U)?

Just as a quick recap: Think of a Rack Unit (U) as the standard way we measure the vertical height for equipment that goes into a server rack. One 1U space is equal to 1.75 inches (that’s about 44.45 mm).

What is a Rack Hole?

So, these rack holes are the specific spots drilled into the rack rails where you make your connections for mounting equipment. They aren’t just scattered randomly, though. The key thing is they come in specific groups along the rail, and these groups are spaced out to exactly match the standard U sizes. One of these hole groups marks out the height of one U.

How Do Rack Holes Relate to Rack Units?

  • For 1U of equipment, there are three holes on the rack.
  • The holes are spaced consistently:
    • Top-to-middle gap: 0.625 inches (15.875 mm)
    • Middle-to-bottom gap: 0.625 inches
    • Bottom-to-next top gap: 0.5 inches (12.7 mm)

Common Rack Unit Applications

Different gear usually comes in certain U sizes based on needs like space or cooling. Knowing these helps plan your rack.

U SizeTypical Gear You’ll See
1UNetwork switches, firewalls, small servers, patch panels. Good for saving vertical space.
2UStandard servers, storage servers, common UPS batteries. Need more internal space.
3UOlder or specialized gear like tape libraries, and dense storage. Less common for new servers.
4UBig storage arrays, GPU servers, large UPS. Need significant height.
5U+Very large systems, modular batteries, custom gear.

This gives you a quick idea of how much space different types of IT equipment usually need.

결론

Getting a handle on Rack Units (U) is key to managing server racks and 서버 랙 배터리. Understanding U means you can pick gear that fits, plan your space right, and keep everything organized. It simplifies installation and helps maximize your vertical space efficiently

카마다 파워 as Professional 서버 랙 배터리 manufacturer in china, customised server rack battery according to requirements. 카마다 파워에 문의 견적 받기.

댓글

더 많은 블로그

블로그에서 리튬 배터리 산업에 대한 더 많은 지식과 트렌드를 알아보세요.

서버 랙에서 랙 유닛 U는 무엇을 의미합니까?

서버실에 들어가거나 랙을 보는 것만으로도 처음에는 혼란스러워 보일 수 있습니다. 저 많은 장비를 어떻게 다 넣을 수 있을까요? 랙 유닛, 즉 "U"가 바로 여기에 있습니다. 랙 유닛은 서버 랙의 수직 공간에 대한 표준 척도입니다. 서버 하드웨어를 다루는 사람이라면 누구나 'U'를 이해하는 것이 중요합니다.

더 읽기"

벽걸이형 배터리와 서버 랙 배터리 중 어떤 것이 가장 적합할까요?

정전, 높은 전기 요금, 에너지 독립을 추구하는 경우 등 어떤 상황에서든 올바른 에너지 스토리지를 선택하는 것은 매우 중요합니다. 배터리를 결정한 후에는 세련된 벽면 장착형 배터리와 기능적인 서버 랙 장착형 배터리라는 중요한 갈림길이 나타납니다. 어떤 길이 귀하에게 적합할까요? 중국 카마다 파워 배터리 전문가로서

더 읽기"

에너지 저장 시스템에서 ESS는 무엇을 의미할까요?

에너지 저장 시스템에서 ESS는 무엇을 의미하나요? 에너지에 대해 이야기해 봅시다. 환경은 빠르게 변화하고 있습니다. 태양광과 풍력 발전은 빠르게 성장하고 있지만, 기존 전력망은 이러한 역동적인 흐름에 적합하게 구축되지 않았습니다. 미국 가정과 기업은 정전 시에도 안정적인 전력과 낮은 요금이 필요합니다. 이것이 바로 에너지 저장 시스템, 즉 ESS가 필요한 이유입니다.

더 읽기"
카마다 파워 로고

방문자가 웹사이트의 모든 페이지에서 귀하의 비즈니스에 대해 알 수 있도록 비즈니스를 요약하세요.

연락하기

123 메인 스트리트
뉴욕, NY 10001

© 2025 판권 소유.

문의

저희 팀이 20분 안에 최적의 제안을 보내드립니다.